"...Known for high end laser particle counters, Lighthouse,
offers a line of remote liquid particle counters for water..."
Remote LPC 0.1
0.1 - 0.5 microns,
4 Channels, 100 mL/Minute
Remote LPC 0.2
0.2 - 2.0 microns,
4 Channels, 100 mL/Minute
Remote LPC 0.5
0.5 - 5.0 microns,
4 Channels, 100 mL/Minute
Do you need real time, continuous monitoring of particles
in your water?
Designed as a dedicated sensor, the LPC (Liquid Particle Counter) series
will constantly feed real time data from 4 different particle size channels
to your central computer system.
With a strong background in programming, Lighthouse is the industry leader
for designing complete Facility Monitoring Systems (FMS). A remote
system from Lighthouse will give you accurate information about your water when it happens.
In fact, dedicated remote liquid particle counters with multiple size
channels are the most advanced and precise way to track contamination events
as well as collect data for trend analysis. Real time alarms help you
contain particle contamination and minimize product loss.
Call 1-877-688-2703 for help designing a remote liquid particulate monitoring system for
your facility or project.
Benefits of Lighthouse Liquid Particle Counters


|
Technical Specifications |
LPC 0.1 |
LPC 0.2 |
LPC 0.5 |
| Size Range |
0.1 – 0.5 µm |
0.2 - 2.0 microns |
0.5
– 5.0 µm |
| Channel Sizes |
Standard: 0.1, 0.2, 0.3, 0.5 |
Standard: 0.2, 0.3, 0.5, 1.0
Standard: 0.2, 0.5, 1.0, 2.0
Optional:0.5 - 5.0 μm |
Standard: 0.5, 0.7, 1.0, 2.0
Standard: 0.5, 1.0, 2.0, 5.0 |
| Laser Source |
Laser Diode |
(same) |
(same) |
| Flow Rate |
100ml/min |
(same) |
(same) |
| Calibration |
NIST Traceable |
(same) |
(same) |
| Data Storage |
250 Samples |
(same) |
(same) |
| Communication
Modes |
RS-232 via RJ45 to PC, RS485/Modbus, Optional
Ethernet |
(same) |
(same) |
| LED Indicators |
Power, Service, Sampling |
(same) |
(same) |
| Supporting
Software |
LMS Express, LMS Express RT, LMS Express RT+,
LMS Net |
(same) |
(same) |
| Concentration Limit |
64,000 counts/ml @ 5% Coincidence Loss |
4,000 counts/ml @ 5%
Coincidence Error |
4,000 counts/ml @ 5% Coincidence Error |
| External
Alarm Output |
Normal Open Dry Contact Rated 0 – 60v AC/DC 1
Amp |
(same) |
(same) |
| Enclosure |
Stainless Steel |
(same) |
(same) |
|
Sample Inlet/Outlet Connection |
1/4” Flaretek™ |
(same) |
(same) |
| Sample Temperature |
32 - 302°F (0 – 150 °C) |
(same) |
(same) |
| Sample
Pressure |
150 PSI |
(same) |
(same) |
| Wetted Surface Materials |
Quartz, PTFE, PFA |
(same) |
(same) |
| Power |
24V DC |
(same) |
(same) |
| Dimensions |
5.7”(L) x 5.2”(W) x 3”(H) [14.47 x 13.2 x 7.6
cm] |
5.7”(L) x 5.0”(W) x 3”(H) [14.47 x 12.7 x 7.6 cm] |
5.7”(L) x 5.2”(W) x 3”(H) [14.47 x 13.2 x 7.6 cm] |
| Weight |
3.5 lbs (1.58 kg) |
3.45 lbs (1.56 kg) |
3.5
lbs (1.58 kg) |
| |
|
Environmental Conditions |
| Operating |
50°F to 104°F (10°C to 40°C) / 20% to 95%
non-condensing |
| Storage |
14°F to 122°F (-10°C to 50°C) / Up to 98%
non-condensing |
| |
|
Accessories |
| Included |
Operating Manual on CD, Power Supply |
| Optional |
Flow Control Device, Sample Tubing, Cabling,
LMS Express, LMS Express RT, LMS Express RT+, LMS Net |
|
 |