Trion Air Boss Cyclone Dust Collectors
|
|

  
- Very Good
Call for
accurate pricing!
 |
"...Efficient and Cost-Effective..."
The Trion Air Boss® Cyclone Separators are among the
more efficient and cost-effective cyclone dust collectors available. Air Boss
Cyclones can be manufactured in capacities from 800 CFM to 13,000 CFM and
effectively remove moderate to large-sized particles from the air stream.
Fans are self-cleaning, material handling, radial blades designed to deliver
peak airflow, and the low Hp saves energy.
The centrifugal action of the Cyclone, created
by rapid rotation of the high velocity air stream, works like a tornado and
forces the
dust out through the bottom of the Cyclone and into a collection drum or
hopper for the specific application. Standard dust storage capacities vary
from 7.5 cu. ft. to 110 cu. ft., with special hopper configurations
available. All models can be housed indoors or outdoors.
 |
|
About the Trion Air Boss Cyclone Dust
Collectors... |
|
Options
- After-filter assemblies
- Access doors
- Sprinkler heads
- Increased hopper clearance
- Explosion venting
- Non-sparking aluminum
fan wheels
- Rotary air locks
- Silencers
Common Applications
- Woodworking
- Buffing and polishing
- Powders (material handling)
- Rubber grinding
- Abrasive cutting
- Metal grinding
- Pre-cleaning (cartridge/baghouses)
|

 |
|
Features |
Benefits |
|
Heavy-duty construction |
Long
collector life |
|
Tapered
cone design |
High
constant efficiency for large particulates provides a
cleaner work environment |
|
No
internal moving parts |
Reduced
maintenance |
|
Various
sizes and configurations |
Wide
range of capacities to meet application requirements |
|
Radial blade material
handling fan |
Delivers peak airflow with the lowest horsepower |
|
Small
footprint |
Saves
valuable floor space |
|
After-Filter Options & Specifications |
|
After-filters provide an
additional level of particle removal. After the cyclone
pulls medium and large particles from the air-stream, small
particles exit the cyclone from the blower outlet.
These small particles need to be eliminated before air is
suitable for breathing. They are too small for the
human body to filter and will become lodged in lung tissue,
causing health problems. The proper after-filter will
capture small particles and return pure air worth breathing.
|
Standard After-Filters: Standard
felt polyester after-filters can be direct-mounted to the
Cyclone or remotely installed with connecting ductwork.
Filters are connected to plenum with hose clamps. Other media
filters are available, as well as optional foam-lined inlet
plenums for sound attenuation. |
|
After-Filter Model |
Length |
Width |
Number of Filters |
Filter Length |
Filter Area (sq. ft.) |
Used with Cyclone Models |
|
DCC-AF4 |
56" |
34" |
4 |
72" |
72 |
DCC-162, -203, -205 |
|
DCC-AF6 |
69" |
34" |
6 |
72" |
108 |
DCC-247, -2410 |
|
DCC-AF9 |
80" |
47" |
9 |
72" |
162 |
DCC-247, -2410 |
|
DCC-AF12 |
93" |
47" |
12 |
72" |
218 |
DCC-3010, -3015 |
|
DCC-AF18 |
130" |
47" |
18 |
72" |
324 |
DCC-3620, -3625 |
|
DCC-AF24 |
156" |
47" |
24 |
72" |
432 |
DCC-4030, -4040 |
|
DCC-AF27 |
178" |
47" |
27 |
72" |
486 |
DCC-4030, -4040, -4440, -4450 |
|
DCC-AF36 |
229" |
47" |
36 |
72" |
648 |
DCC-4440, -4450 |
|
Right:
After-filters and after-filter housings.
(E) After-filter housings are designed for indoor use only.
(W) After-filter housings are designed for outdoor installations. |
DCC-AF4 |
DCC-AF-18W |
DCC-AF-27W |
DCC-AF-9E |
 |
 |
 |
 |
|
Enclosed After-Filters E-W: Housed felt polyester
assembled after-filter is connected to the Cyclone with
ductwork. Other media filters are available. Standard options
are weather enclosures, sprinkler heads and foam-lined inlet
plenums for sound attenuation. |
|
Enclosed After-Filter Model |
Length |
Width |
Height |
Number of
Filters |
Filter Area (sq. ft.) |
Hopper Discharge |
Used with Cyclone Models |
|
DCC-AF4 E/W |
56" |
42" |
144" |
4 |
72 |
(1) 10" |
DCC-162, -203, -205 |
|
DCC-AF6 E/W |
69" |
42" |
156" |
6 |
108 |
(1) 10" |
DCC-247, -2410 |
|
DCC-AF9 E/W |
80" |
55" |
156" |
9 |
162 |
(1) 10" |
DCC-247, -2410 |
|
DCC-AF12 E/W |
93" |
55" |
167" |
12 |
218 |
(1) 10" |
DCC-3010, -3015 |
|
DCC-AF18 E/W |
130" |
55" |
156" |
18 |
324 |
(2) 10" |
DCC-3620, -3625 |
|
DCC-AF24 E/W |
156" |
55" |
167" |
24 |
432 |
(2) 10" |
DCC-4030, -4040 |
|
DCC-AF27 E/W |
178" |
55" |
156" |
27 |
486 |
(3) 10" |
DCC-4030, -4040, -4440, -4450 |
|
DCC-AF36 E/W |
229" |
55" |
156" |
36 |
648 |
(3) 10" |
DCC-4440, -4450 |
|
|
See our
entire line of Cyclone Dust
Collectors,
Dust Collectors and
Industrial Air Purifiers.
If you
have any questions, call us, we'll be glad to help!
1-877-688-2703
Return Policy |
Contact Us | About Us
|
View Cart |
Check Out
©2001 - 2006 - BPA Air Quality Solutions
LLC
(DBA BreathePureAir.com) is for educational and research intentions only and
is not intended as an alternative for medical treatment or advice. Use of
this website, the 90 day return policy, and free shipping is subject to our
published
privacy policy,
terms of service,
and return policy.
|
|