Trion Air Boss T-5200 Owners Manual: Installation

Back to Trion AirBoss T-Series
Trion AirBoss T-Series
T-5200 Owners Manual
1.  Power Requirements
2.  Preparation for Installation
3.  Installation
4.  Maintenance
5.  Replacement Parts
6.  Warranty
7.  Troubleshooting Guide
8.  Diagrams

INSTALLATION – READ THOROUGHLY

  1. Carefully unpack unit from shipping crate or carton and examine for damage in shipment.

  2. Remove ionizer/collector cell(s), pre-filters and after-filters.

  3. Attach 600 pound test chain to the ceiling joist using:

    1. Wood joist – 1/2” (13mm) eye bolts

    2. Metal joist – wrap chain around joist at least twice and secure with 600 pound test connecting link

  4. Chain should be cut to allow the unit to hang from a predetermined height from the floor. (Usually 10-12 feet or 3.0-3.6 m).

  5. The unit is equipped with a locator dimple in each corner on the top and bottom and (1) eahc on the approximate mid point edge of the top and bottom. Using the dimples as a guide, drill (6) 19/32” dia. holes that will be required for mounting the eyebolts, which are attached to the suspension chain.Chain supported installation for Trion AirBoss T5200

  6. Screw a 1/2"-13 x 1-1/4" long eye bolt (or larger) in each hole.  The T5200 unit is supleid with weld nuts at each dimple location.

  7. Using 1/2” connecting links, attach unit to chain. Use turnbuckles on diagonally opposite chains.
    NOTE: Foul threads on turnbuckles after leveling unit to ensure that the turnbuckle will not "“back off" or loosen and cause the unit to fall.

  8. The units can be suspended with the direction of airflow from the right to left. If a left to right airflow is desired, the unit may be flipped over and the eyehooks installed in what was originally the bottom.

LIQUID AEROSOL APPLICATION INSTALLATIONS
The unit is equipped with a sump, drain hole sized to accept a ½” NPT fitting.

For the collection of liquid contaminant:

  1. Install drain fitting to allow for the attachment of a liquid collection cup or drain hose. A drain fitting is available from your representative. An “S” trap is required in the drain hose to ensure proper drainage of the collected liquid.

  2. Raise the front corner of the unit, opposite of the drain corner, ½” (13 mm) to enable the collected liquid to flow to the drain sump.

Contaminants to be collected – such as oils in vaporous state – must be condensed into particulate form prior to entering the ionizing-collecting cells in order to maintain the anticipated efficiency. Gases, vapors or any nonparticulate cannot be precipitated and will therefore pass through the air cleaner. Any condensing that takes place downstream from the air cleaner defeats the purpose. Similarly, heavy concentrations of water vapor, or other matter that becomes highly conductive when condensed, must be prevented from entering and/or condensing in the collecting elements to prevent electrical arc over and shorting.

ELECTRICAL INSTALLATION
All units must be wired directly into the terminal block in the component box on the access door side of the unit. Use NEC Class I wiring methods. Size branch circuit protection in accordance with the NEC. Refer to the appropriate enclosed wiring diagram in the attached figures.

 WARNING

EXERCISE ALL THE NORMAL PRECAUTIONS WHEN WORKING WITH HIGH VOLTAGE AND COMPLY WITH NEC AND ALL APPROPRIATE LOCAL CODES.

Check Out for System Start-up
When the installation has been completed, assure that the equipment is ready for start-up by checking the following:

  1. All construction debris is removed from the ionizing/collecting
    cells, drain connections and ductwork.

  2. The drain line from the Trion drain basin is clear and
    completely connected to its point of termination.

  3. Supply line power is available and electrical wiring
    is completed to the junction box.

 

See the full Trion AirBoss T-Series line of industrial electronic air cleaners.


See our entire line of Smoke Eaters, Ambient Air Cleaners, Mist Eliminators, Fume Extractors or all Industrial Air Purifiers.

If you have any questions, call us, we'll be glad to help!

1-877-688-2703

Contact Us  |  About Us 

©2001 - 2006 - BPA Air Quality Solutions LLC
(DBA BreathePureAir.com) is for educational and research intentions only and is not intended as an alternative for medical treatment or advice. Use of this website, the 90 day return policy, and free shipping is subject to our published privacy policy, terms of service, and return policy.