for T-5200
Owners Manual
The following instructions are for use by
qualified personnel.
|
WARNING |
RISK OF ELECTRIC SHOCK
These serving instructions are for use by qualified personnel
only. To reduce the risk of electric shock, do not perform any
servicing other than that contained in the operating
instructions unless you are qualified to do so. |
|
SAFETY
NOTE |
| Factory designed access to all
electrically charged high voltage components contain electrical
interlocks for the safety of operating personnel. Any additional
access that may be provided in the system, where there is access
to high voltage, must be equipped with such interlocks.
Interlocks are readily available from the factory. |
CLEANING
To maintain optimum collection efficiency, the pre-filters and
ionizer/collector cells should be removed periodically and soaked in a
solution of hot water and Trion Tridex detergent for 2 to 4 hours, rinsed
thoroughly and then air dried completely before reinstalling in the unit.
The frequency of cleaning is dependent on the type of contaminant being
collected. Liquid aerosol requires less cleaning while welding smoke may
require more frequent cleaning.
NOTE: Trion Tridex Detergent is specially formulated
for use with Trion electronic air cleaners. Use of other cleaners and
detergents, not specifically approved by Trion, can cause possible failures
in the unit and will void any and all warranties on our equipment.

WASH IONIZING / COLLECTING CELLS
|
WARNING |
| DO NOT USE HIGH PRESSURE STEAM
CLEANING EQUIPMENT TO CLEAN CELLS. THE EXCESSIVE HEAT AND
PRESSURE WILL CAUSE THE PLATES TO WARP AND IN TURN POSSIBLY
CAUSE EXCESSIVE ARCING. |
-
Turn the control switch “OFF” and disconnect
power to the unit.
-
Open the cell access door.
-
Remove ionizer/collector cells and wash in
HOT detergent water. If the collected contaminant is of extremely dry
nature, it can be blown off the cells with a pressure hose or by gently
tapping the end plate of the cell.
-
Remove the mechanical pre-filter. Remove
collected dust or lint by vacuuming or brushing. Wash with warm, soapy
water.
-
Rinse all components thoroughly in warm,
clear water and allow to drip dry completely.
-
Replace pre-filters and ionizer/collector
cells. ENSURE the airflow arrows point in the direction of airflow
(towards the blower).
-
Close the access door; reconnect power to
the unit.
-
Turn control switch to “ON”. If arcing
occurs or the indicating light flickers, the components may still be
damp. Turn the unit OFF and allow the cells to dry completely.
INSPECTIONS
The motors and blowers on Trion T1300 and T2600 air cleaners
have sealed ball bearings and never need lubricating.
Belt tension should be checked periodically. When a moderate force is
applied to the belt midway between the pulleys, the belt should deflect
approximately ˝ “ (13 mm).
CAUTION: Having too much tension on the belts will shorten the
belt life and place undue stress on the motor and blower bearings.
See the full
Trion AirBoss T-Series line of
industrial electronic air cleaners.
See our entire
line of
Smoke Eaters,
Ambient Air Cleaners,
Mist
Eliminators,
Fume
Extractors or all
Industrial Air Purifiers.
If you have
any questions, call us, we'll be glad to help!
1-877-688-2703
Contact
Us | About Us
©2001 - 2006 - BPA Air Quality Solutions
LLC
(DBA BreathePureAir.com) is for educational and research intentions only and
is not intended as an alternative for medical treatment or advice. Use of
this website, the 90 day return policy, and free shipping is subject to our
published
privacy policy,
terms of service,
and return policy.
|