 WARNING

RISK OF ELECTRIC SHOCK
These serving instructions are for use by qualified personnel only. To reduce the risk of electric shock, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so.

 

 SAFETY NOTE

Factory designed access to all electrically charged high voltage components contain electrical interlocks for the safety of operating personnel. Any additional access that may be provided in the system, where there is access to high voltage, must be equipped with such interlocks. Interlocks are readily available from the factory.

CLEANING
To maintain optimum collection efficiency, the pre-filters and ionizer/collector cells should be removed periodically and soaked in a solution of hot water and Trion Tridex detergent for 2 to 4 hours, rinsed thoroughly and then air dried completely before reinstalling in the unit. The frequency of cleaning is dependent on the type of contaminant being collected. Liquid aerosol requires less cleaning while welding smoke may require more frequent cleaning.

NOTE:  Trion Tridex Detergent is specially formulated for use with Trion electronic air cleaners. Use of other cleaners and detergents, not specifically approved by Trion, can cause possible failures in the unit and will void any and all warranties on our equipment.

WASH IONIZING / COLLECTING CELLS

 WARNING

DO NOT USE HIGH PRESSURE STEAM CLEANING EQUIPMENT TO CLEAN CELLS. THE EXCESSIVE HEAT AND PRESSURE WILL CAUSE THE PLATES TO WARP AND IN TURN POSSIBLY CAUSE EXCESSIVE ARCING.
  1. Turn the control switch “OFF” and disconnect power to the unit.

  2. Open the cell access door.

  3. Remove ionizer/collector cells and wash in HOT detergent water. If the collected contaminant is of extremely dry nature, it can be blown off the cells with a pressure hose or by gently tapping the end plate of the cell.

  4. Remove the mechanical pre-filter. Remove collected dust or lint by vacuuming or brushing. Wash with warm, soapy water.

  5. Rinse all components thoroughly in warm, clear water and allow to drip dry completely.

  6. Replace pre-filters and ionizer/collector cells. ENSURE the airflow arrows point in the direction of
    airflow (towards the blower).

  7. Close the access door; reconnect power to the unit.

  8. Turn control switch to “ON”. If arcing occurs or the indicating light flickers, the components may still be damp. Turn the unit OFF and allow the cells to dry completely.

INSPECTIONS
The motors and blowers on Trion T1300 and T2600 air cleaners have sealed ball bearings and never need lubricating.

Belt tension should be checked periodically. When a moderate force is applied to the belt midway between the pulleys, the belt should deflect approximately ˝ “ (13 mm).

CAUTION:  Having too much tension on the belts will shorten the belt life and place undue stress on the motor and blower bearings.

 

See the full Trion AirBoss T-Series line of industrial electronic air cleaners.


See our entire line of Smoke Eaters, Ambient Air Cleaners, Mist Eliminators, Fume Extractors or all Industrial Air Purifiers.

If you have any questions, call us, we'll be glad to help!

1-877-688-2703

Contact Us  |  About Us 

 

©2001 - 2006 - BPA Air Quality Solutions LLC
(DBA BreathePureAir.com) is for educational and research intentions only and is not intended as an alternative for medical treatment or advice. Use of this website, the 90 day return policy, and free shipping is subject to our published privacy policy, terms of service, and return policy.